90 dB · Risk
  • Safe · under 65 dB
  • Caution · 65–85 dB
  • Risk · over 85 dB

OSHA’s noise standard sets two numbers that matter most. The permissible exposure limit is 90 dBA averaged over an 8-hour workday, and the action level is 85 dBA. At 85 dBA, employers must start a hearing conservation program and offer hearing protection at no cost. Above 90 dBA, workers must wear it, and the employer must try to bring the noise down.

The rule is 29 CFR 1910.95, which covers general industry in the US. Construction has its own, shorter rule. This guide explains both in plain language. It is a summary, not legal advice; check the regulation itself or OSHA for your situation.

What is the OSHA noise exposure limit?

OSHA uses a time-weighted average (TWA): the average level over the workday, measured in A-weighted decibels (dBA) with a slow meter response. The limit is 90 dBA for 8 hours.

OSHA uses a 5 dB exchange rate. Every 5 dB increase halves the time allowed. This is Table G-16 in the standard:

Sound level (dBA, slow)OSHA allowed time per dayNIOSH recommended time
85No limit (action level)8 h
908 h2.5 h
926 habout 1.5 h
954 habout 47 min
973 h30 min
1002 h15 min
1021.5 habout 9.5 min
1051 habout 5 min
11030 minabout 1.5 min
11515 min or lessabout 28 s

OSHA’s table stops at 115 dBA: continuous exposure above that is not allowed. For impulse or impact noise, such as a nail gun or a drop forge, the standard says the level should not exceed 140 dB peak.

When is hearing protection required?

This is the question most people searching for the standard want answered, and the answer has two steps.

At 85 dBA (8-hour TWA): employers must provide it. Section 1910.95(i) says hearing protectors must be made available to all employees exposed at or above an 8-hour average of 85 dBA, at no cost, and replaced as needed. Workers must be able to choose from a variety of suitable protectors.

Wearing it is mandatory when:

  • the worker’s exposure is above the 90 dBA limit, or
  • the worker is exposed at 85 dBA or more and either has not yet had a baseline hearing test, or has had a standard threshold shift, a measurable worsening of hearing.

The protection must bring the worker’s exposure down to 90 dBA, or to 85 dBA for workers who have had a threshold shift.

Hearing protection is not meant to be the first fix above 90 dBA. OSHA expects feasible engineering or administrative controls, such as quieter machines, enclosures or shorter shifts in noisy areas, with protection covering what is left.

What is a hearing conservation program?

Once any worker reaches the 85 dBA action level, OSHA requires a hearing conservation program. Its main parts:

  1. Noise monitoring. Identify who is exposed at or above 85 dBA, using area measurements or personal dosimeters, and repeat when equipment or processes change. Workers must be told their results.
  2. Hearing tests (audiometry). A baseline audiogram within 6 months of first exposure at the action level (1 year if a mobile test van is used), then a new test at least once a year. Workers should avoid loud non-work noise for 14 hours before the baseline test.
  3. Follow-up on hearing changes. A standard threshold shift is an average worsening of 10 dB or more at 2000, 3000 and 4000 Hz in either ear. The worker must be told in writing within 21 days, and their hearing protection checked, refitted or upgraded.
  4. Hearing protection as described above, with fitting and training.
  5. Training every year on the effects of noise, how protectors work and why the tests matter.
  6. Records. Noise measurements kept for 2 years and hearing test records for the length of employment.

Under OSHA’s injury recordkeeping rule, a threshold shift that also leaves average hearing at 25 dB or worse must be recorded as an occupational hearing loss case.

How is noise dose calculated?

When the level changes through the day, OSHA adds up each period as a fraction of its allowed time. The result is the noise dose:

Dose (%) = 100 × (C1/T1 + C2/T2 + …)

C is the time actually spent at a level, and T is the time allowed at that level from the table. A dose of 100% equals the 90 dBA limit. A dose of 50% equals the 85 dBA action level.

Example: 4 hours at 90 dBA plus 2 hours at 95 dBA gives 4/8 + 2/4 = 1.0, a dose of 100%. That worker is at the legal limit, even though neither period alone looked excessive. A dosimeter or a meter app with a dose readout does this sum for you.

How is OSHA different from NIOSH?

NIOSH, the National Institute for Occupational Safety and Health, is the research agency that advises on workplace health. Its recommended limit is stricter:

OSHA (legal limit)NIOSH (recommendation)
8-hour limit90 dBA85 dBA
Exchange rate5 dB3 dB
100 dBA allowed for2 hours15 minutes
Peak limit140 dB140 dB
StatusEnforceable in US workplacesHealth-based guidance

The 3 dB exchange rate follows the physics: +3 dB is double the sound energy. NIOSH estimates that a meaningful share of workers exposed at 90 dBA for a whole career will still develop hearing loss, which is why many employers and hearing professionals use the NIOSH numbers as their own target. For a broader look at both rules, see how loud is too loud.

What about construction and other industries?

  • Construction falls under 29 CFR 1926.52. It uses the same 90 dBA limit, the same 5 dB exchange rate and the same 140 dB peak limit, and it requires a “continuing, effective” hearing conservation program when exposures exceed the limit. It does not spell out the program in the same detail as 1910.95.
  • Mining is regulated by MSHA, not OSHA, under a separate noise rule with a similar 90 dBA limit and 85 dBA action level.
  • State plans, such as Cal/OSHA, must be at least as effective as federal OSHA and can be stricter.

How do earplug ratings fit in?

Protectors carry a Noise Reduction Rating (NRR). The rating comes from lab tests, and real-world protection is usually lower. The OSHA Technical Manual gives inspectors two ways to use it with A-weighted measurements:

  • To check whether protection is adequate, subtract 7 from the NRR: protected level ≈ TWA − (NRR − 7).
  • To decide whether engineering controls are needed, also apply a 50% safety factor: protected level ≈ TWA − (NRR − 7) × 50%.

Take a worker at 100 dBA wearing NRR 29 earplugs. The first method gives 100 − 22 = 78 dBA. The more cautious second method gives 100 − 11 = 89 dBA. Either way, the protection only works if the plugs are inserted correctly and worn for the whole shift. Fit matters more than the number on the box.

How do you measure workplace noise?

OSHA compliance measurements use a Type 2 or better sound level meter or a personal noise dosimeter, set to A-weighting and slow response, calibrated before and after use. Personal dosimeters are clipped near the worker’s shoulder for a full shift.

A phone is not a compliance instrument. It is a good screening tool, though: if a quick reading in a work area shows 85 dBA or more, that is a sign the area needs proper monitoring. NIOSH also has a rule of thumb: if you need to raise your voice to be heard by someone an arm’s length away, the level is probably 85 dBA or more. The decibel chart shows which everyday tools and machines sit in that range, and our iPhone measuring guide covers phone accuracy.

Screening noise with your phone

Decibel Meter: dB Sound Level for iPhone and Apple Watch measures in dBA with slow or fast response, records Leq, maximum and peak, and calculates a noise dose under either the OSHA or the NIOSH rule, so you can see which work areas and tasks need a closer look. It does not replace a calibrated meter or dosimeter for compliance. The app is free to download, and live measuring is part of the subscription. See what the app does, or run a quick check with the free online meter in your browser.

Questions

At what decibel level is hearing protection required by OSHA?

Employers must offer hearing protection free of charge to anyone exposed to an 8-hour average of 85 dBA or more. Workers must wear it when their exposure is above the 90 dBA limit, or from 85 dBA if they have had a standard threshold shift or have not yet had a baseline hearing test.

What is the OSHA noise exposure limit?

The permissible exposure limit is 90 dBA as an 8-hour time-weighted average. The allowed time halves for every 5 dB increase, so 95 dBA is allowed for 4 hours and 100 dBA for 2 hours. Impulse noise should not exceed 140 dB peak.

What is the OSHA action level for noise?

The action level is an 8-hour time-weighted average of 85 dBA, or a noise dose of 50%. From that point the employer must monitor noise, provide free hearing protection, offer annual hearing tests and train workers.

How is the OSHA limit different from NIOSH?

NIOSH, the US research agency for workplace health, recommends a stricter limit of 85 dBA for 8 hours with a 3 dB exchange rate. Under NIOSH, 100 dBA is safe for 15 minutes a day, while OSHA allows 2 hours. OSHA's limit is the legal one; NIOSH's is the health-based recommendation.

Does the OSHA noise standard apply to construction?

Construction is covered by a separate rule, 29 CFR 1926.52, with the same 90 dBA limit and 5 dB exchange rate. It requires a hearing conservation program when exposures exceed the limit, but it is less detailed than the general industry standard.

Sources

  1. OSHA — Occupational Noise Exposure, 29 CFR 1910.95
  2. OSHA — Noise: Standards
  3. OSHA — Occupational Noise Exposure in Construction, 29 CFR 1926.52
  4. OSHA Technical Manual — Noise
  5. NIOSH — Noise and Occupational Hearing Loss